TURP

 
 
Set-Up:

Resectascope set up:

PUT TOGETHER AND NEVER TAKE APART

22 outersheeth

inner sheeth

PLACE TO THE SIDE

Next:

Place together

Visual/Nonvisual Obturator

Lens

PUT ALL TOGETHER Place to the side

 

NEXT SET UP RESECTION ELEMENT

Pipolar cautery tool place in bipolar resection element

place bipolar wire into resection element

 

ELLIK SET UP:

Water-Type:

NS = bipolar

Sterile Water=Monopolar

 

PROCEDURE NOTES

stop 1 cm cephalad to very, help prevent retrograde ejec. Then go around side

High median bar is high bladder neck

Prostate is pressed, then parts removed ti will rebound back due to spring release of pressure

Know go too far when reach capsule (fibrous tissue)

T:40cc in 22F 30cc foley

 

10 lasix at end of case

Tramadol

Colace

 

1hr traction, then off traction for 30-40 minutes to check for bleeding

light pink is okay

come back 48-72hr for TOV

T: Tape to keep foley on 

Bond on large part of leg

silk tape large over area

Tape around foley pulling down x3

put 4x4 around foley base

put silk tape on top

 

Flush foley with 60cc to check bleeding